Power Distribution

Incoming changeover and feeder protection sit above the branch MCBs. Use ATS for dual source and MCCB / high-frame MCB for the riser.

Browse Cases
HOW IT IS USED

Incoming ChangeoverAnd Feeder Breakers

A small mains/generator board uses Q3R-63 or Q5-100 4P ATS.

Larger feeders use Q5-630 4P ATS.

Downstream, WTCM1-250 MCCB or DZ47-125 (63-125A) protects the riser.

WTXU-03 watches the three-phase incoming.

WTSP-A40 sits on the AC bus.

Q5-630 is a 4P dual-power ATS for AC 100-220V class control.

Q5-100 is the 100A-class 4P ATS.

WTCM1-250 is the moulded-case feeder breaker in this catalog.

  • Q3R-63: 4P ATS
  • Q5-100: 4P ATS
  • Q5-630: 4P ATS
  • WTCM1-250: MCCB feeder
  • DZ47-125: 63-125A
  • WTXU-03: phase monitor
Incoming Changeover
4P
ATS Pole Count
100A
Q5-100 Class
630A
Q5-630 Class
250A
WTCM1-250 MCCB
THE CHALLENGE

Keep The Riser Alive And Selective

Incoming ATS and feeder MCCB must clear a fault without dropping every downstream DZ47 way.

Mains / generator changeover
WTAIDQ DEVICE

Mains / generator changeover

Q3R-63 4P for compact essential boards. Q5-100 4P when the incoming is 100A class. Q5-630 4P for larger dual-source feeders, AC 100-220V control range.

  • Q3R-63 4P ATS
  • Q5-100 4P ATS
  • Q5-630 4P ATS
Feeder short-circuit
WTAIDQ DEVICE

Feeder short-circuit

WTCM1-250 MCCB on the outgoing feeder. For 63-125A compact incoming use DZ47-125 (63/80/100/125A). Branch ways stay on DZ47-63 4.5kA.

  • WTCM1-250 MCCB
  • DZ47-125 63-125A
  • DZ47-63 4.5kA branches
Incoming voltage and surge
WTAIDQ DEVICE

Incoming voltage and surge

WTXU-03 (true RMS, 45-65Hz) blocks close-in on phase loss. WTSP-A40 clamps AC surges on the same incoming bus.

  • WTXU-03 voltage relay
  • WTSP-A40 AC SPD
  • DIN-rail control section
PRODUCTS

Devices For Incoming And Feeders

ATS, MCCB, high-frame MCB, voltage relay and AC SPD.

WTCM1-250 Moulded Case Circuit Breaker

Circuit Breaker

High Current Rating: Rated current from 100A to 250A on the WTM1-250, with the WTM1 series spanning 16A to 1250A for DC distribution. DC Voltage Coverage: DC operating voltage of 550V in 2P, 750V in 3P and up to 1500V View WTCM1-250 Moulded Case Circuit Breaker →

TYPICAL LAYOUTS

Board Tiers

Size ATS and MCCB from the incoming current on the single-line diagram.

Small dual-source board

Q3R-63 4P ATS + DZ47-63 ways + WTSP-A40.

100A incoming

Q5-100 4P ATS. Feeder DZ47-125 or WTCM1-250 depending on breaking-capacity need.

Larger dual-source feeder

Q5-630 4P ATS into WTCM1-250 MCCB outgoing.

Phase-failure interlock

WTXU-03 in the ATS / contactor coil circuit so a lost phase cannot reclose.

COMMON QUESTIONS

Frequently Asked Questions

Discover More
All are 4P dual-power ATS. Q3R-63 is the compact 63A-class unit. Q5-100 is 100A class. Q5-630 is the larger 630A-class frame.
CONTACT US

Start Your Electrical Project Today

Send your application, voltage, certifications and quantity to this electrical protection manufacturer. We reply with a quotation within 24 hours.
  • Engineering review by an electrical protection manufacturer before quoting
  • Plant pricing with no intermediaries
  • Export packing and shipping handled in one place
  • One order owner from quotation to delivery