Smart Grid & IoT

Remote boards need a breaker that already measures and talks. WTB2-80ML reports current, voltage, leakage and temperature over 4G or WiFi.

Browse Cases
HOW IT IS USED

Metering And TripIn One Device

Replace a plain MCB with WTB2-80ML when the site must be read and opened remotely.

The 2P device is AC 230V, In 32/40/50/63/80A, B/C/D curves, 6kA, IΔn 30/50/100/300mA.

It monitors current, voltage, leakage, energy, frequency and temperature.

WTB2-80ML 4G uses RS-485, Bluetooth and 4G.

The WiFi version uses RS-485, Bluetooth and WiFi.

Ambient -25 to +65°C, humidity ≤95%, altitude ≤2000m.

Pair with WTXU-03 on three-phase incoming and Q3R-63 if the site has a generator.

  • WTB2-80ML: 2P, AC 230V
  • In 32-80A, 6kA
  • IΔn 30-300mA
  • 4G or WiFi + RS-485
  • Mech life 20,000
  • Elec life 10,000
Metering And Trip
80A
WTB2-80 Max Current
6kA
Breaking Capacity
230V
Rated Working Voltage
4G/WiFi
Remote Channel
THE CHALLENGE

See The Feeder Without A Site Visit

Unmanned rooms still need overload, leakage and a way to open the circuit from the office.

Remote trip and energy reading
WTAIDQ DEVICE

Remote trip and energy reading

WTB2-80ML 2P, AC 230V, 32-80A, 6kA, B/C/D. Residual 30/50/100/300mA. Wiring up to 25mm². Mechanical life 20,000; electrical life 10,000.

  • Current / voltage / leakage / kWh
  • 4G or WiFi + RS-485 + Bluetooth
  • -25 to +65°C operating range
Three-phase incoming still needs a monitor
WTAIDQ DEVICE

Three-phase incoming still needs a monitor

WTB2-80ML is 2P / 230V. On a three-phase riser keep WTXU-03 (true RMS, 45-65Hz) for phase loss, then feed single-phase ways into WTB2-80ML.

  • WTXU-03 on 3-phase infeed
  • WTB2-80ML on 230V ways
  • Do not treat 2P as 3P
Backup source at the same site
WTAIDQ DEVICE

Backup source at the same site

Q3R-63 4P ATS for generator changeover. WTSP-A40 on the AC incoming so a surge does not take out the smart breaker electronics.

  • Q3R-63 4P ATS
  • WTSP-A40 AC SPD
  • Keep comms power on the ATS essential side
PRODUCTS

Devices For Connected Boards

Smart MCB plus the voltage relay, ATS and SPD that sit around it.

TYPICAL LAYOUTS

Where WTB2-80ML Goes

Use it as the 230V way that must be metered and opened remotely.

Tenant or shop feeder

WTB2-80ML 2P, pick 32-80A and B/C/D from the load. 4G if there is no LAN; WiFi if the site already has it.

Unmanned pump / lighting kiosk

Remote open/close plus leakage 30-300mA. Ambient down to -25°C is inside the listed range.

Three-phase room, single-phase ways

WTXU-03 on the incoming, WTB2-80ML on each 230V outgoing.

Site with generator

Q3R-63 ATS upstream. Put the smart breaker on the load side that you still need to meter after transfer.

COMMON QUESTIONS

Frequently Asked Questions

Discover More
WTB2-80ML 4G: RS-485, Bluetooth, 4G. WTB2-80ML WiFi: RS-485, Bluetooth, WiFi. Both are 2P, AC 230V, 32-80A, 6kA.
CONTACT US

Start Your Electrical Project Today

Send your application, voltage, certifications and quantity to this electrical protection manufacturer. We reply with a quotation within 24 hours.
  • Engineering review by an electrical protection manufacturer before quoting
  • Plant pricing with no intermediaries
  • Export packing and shipping handled in one place
  • One order owner from quotation to delivery