Industrial Automation

Motor starters need a contactor for frequent make/break, a breaker or relay for overload, and a monitor for phase loss. Ratings below are from the live CJX2, MC and WTXU pages.

Browse Cases
HOW IT IS USED

Motor Control AndPanel Monitoring

A DOL or reversing starter uses a CJX2 or MC contactor on the motor line.

WTXU-03 watches three-phase voltage (true RMS, 45-65Hz).

WTKA1-01 watches current.

Time relays handle star-delta or delayed start.

CJX2-2510 is a 25A AC contactor; CJX2-9511 is 95A.

CJX2-D115 is a 115A high-ampere frame.

MC-40a is a 40A magnetic contactor at 220V coil.

WTXU-03 is a 1-module DIN relay with 8 button-set voltage ranges and LED status.

  • CJX2-2510: 25A AC
  • CJX2-9511: 95A AC
  • CJX2-D115: 115A AC
  • MC-40a: 40A, 220V coil
  • WTXU-03: 45-65Hz, true RMS
  • WTKA1-01: current monitor
Motor Control And
25A
CJX2-2510 AC Contactor
95A
CJX2-9511 AC Contactor
115A
CJX2-D115 Frame
45-65Hz
WTXU-03 Frequency
THE CHALLENGE

Start Current And Phase Faults

Motors draw a multiple of FLA at start. The contactor must survive that, and the monitor must drop the coil on phase loss.

Frequent motor start / stop
WTAIDQ DEVICE

Frequent motor start / stop

CJX2-2510 (25A) covers small conveyors and pumps. CJX2-9511 (95A) and CJX2-D115 (115A) cover larger motors. MC-40a is a compact 40A, 220V-coil option for OEM panels.

  • CJX2-2510 25A
  • CJX2-9511 95A
  • MC-40a 40A / 220V coil
Phase loss and voltage drift
WTAIDQ DEVICE

Phase loss and voltage drift

WTXU-03 measures true RMS, 45-65Hz, voltage error <1%, 8 rated voltages set by buttons, 1-module DIN, LED status. It opens the contactor coil before a single-phased motor overheats.

  • True RMS measurement
  • 45-65Hz working range
  • DIN 1-module width
Over-current on a jammed load
WTAIDQ DEVICE

Over-current on a jammed load

WTKA1-01 current monitoring relay sits on the CT or loop and trips when current stays above the set point. Pair it with the CJX2 coil circuit.

  • WTKA1-01 current monitor
  • Works with CJX2 coil circuit
  • DIN-rail panel mount
PRODUCTS

Devices For Motor Panels

AC contactors plus voltage and current monitors from the catalog.

TYPICAL LAYOUTS

Starter And Monitor Pairing

Match FLA to the contactor, then add WTXU / WTKA1 on the control circuit.

Small pump / fan DOL

CJX2-2510 25A or MC-40a 40A. WTXU-03 on the three-phase incoming.

95A class motor

CJX2-9511 95A AC contactor. Add WTKA1-01 if the process jams or overloads often.

115A+ industrial line

CJX2-D115 115A. Higher frames in the same D/F series go to 170A, 245A, 330A and 410A.

Star-delta or delayed start

WTA1 power-on delay or WTT8 / WTM1 time relays in the control circuit.

COMMON QUESTIONS

Frequently Asked Questions

Discover More
Use motor FLA, not just kW. CJX2-2510 is 25A, CJX2-9511 is 95A, CJX2-D115 is 115A. The F series continues to 400A.
CONTACT US

Start Your Electrical Project Today

Send your application, voltage, certifications and quantity to this electrical protection manufacturer. We reply with a quotation within 24 hours.
  • Engineering review by an electrical protection manufacturer before quoting
  • Plant pricing with no intermediaries
  • Export packing and shipping handled in one place
  • One order owner from quotation to delivery