Commercial Buildings

Distribution boards in offices, malls and hotels mix lighting, HVAC and sockets. Overload, leakage and mains loss have to be isolated without shutting the whole floor.

Browse Cases
HOW IT IS USED

Branch Protection InsideThe Panel Board

A typical commercial board starts with incoming changeover, then MCB / RCCB ways for lighting and sockets, plus a modular contactor for timed HVAC or corridor lighting.

WTAIDQ devices are DIN-rail parts that drop into WT-HT surface boxes.

DZ47-63 is a 2P 63A MCB at 230/400V, 4.5kA, IEC 60898-1, C curve.

WTH8-63 switches lighting and HVAC loads at AC 400V, 50/60Hz, IEC/EN 61095.

Q3R-63 4P ATS keeps essential circuits live when the utility fails.

  • DZ47-63: 63A, 4.5kA, 230/400V
  • DZ47-125: 63-125A incoming ways
  • WTH8-63: 63A modular contactor
  • WT-HT 12WAY: 250 x 193 x 105 mm
  • Q3R-63: 4P dual-power ATS
  • WTSP-A40: AC SPD, 40A class
Branch Protection Inside
63A
DZ47-63 Branch Rating
4.5kA
MCB Breaking Capacity
125A
DZ47-125 Incoming
12WAY
WT-HT Box Size
THE CHALLENGE

What The Board Must Stop

Three failures show up most often in commercial risers. Each one maps to a catalog rating, not a generic claim.

Overload on mixed lighting and socket ways
WTAIDQ DEVICE

Overload on mixed lighting and socket ways

A short on one tenant circuit should not black out the floor. DZ47-63 (2P 63A, 230/400V, 4.5kA, IEC 60898-1) sits on branch ways. For larger incoming feeders use DZ47-125 (63/80/100/125A).

  • C-curve thermal-magnetic trip
  • 4.5kA breaking capacity
  • IEC 60898-1, CE / KEMA
HVAC and corridor lighting left running
WTAIDQ DEVICE

HVAC and corridor lighting left running

WTH8-63 (63A, AC 400V, DIN rail, IEC/EN 61095) and WTH8-16 (16A, silver-alloy contacts, arc extinction <15ms) take a BMS or timer signal so fans and lights drop out after hours.

  • 50,000+ mechanical operations
  • 100,000+ electrical cycles
  • DIN-rail modular width
Utility loss and incoming surge
WTAIDQ DEVICE

Utility loss and incoming surge

Q3R-63 4P ATS transfers essential loads to generator. WTSP-A40 AC SPD clamps transients on the incoming bus before they reach contactors and controls.

  • Q3R-63 4P dual-power changeover
  • WTSP-A40 AC surge module
  • Fits WT-HT 12WAY surface box
PRODUCTS

Devices For Commercial Boards

MCB, modular contactor, ATS, SPD and enclosure from the live catalog.

TYPICAL LAYOUTS

Where These Ratings Fit

Use the current and pole count on the drawing, then pick the matching SKU.

Floor distribution board

DZ47-63 2P/4P ways for lighting and sockets. Incoming DZ47-125 when the riser is 80-125A.

HVAC and public lighting

WTH8-16 or WTH8-63 on DIN rail, coil driven by a timer or BMS. WTH8-63 is AC 400V, 50/60Hz.

Lobby / fire essential board

Q3R-63 4P ATS for generator changeover. WTSP-A40 on the incoming AC bus.

Surface enclosure

WT-HT 12WAY box: 250 x 193 x 105 mm. 5WAY and 18WAY sizes are in the same family.

COMMON QUESTIONS

Frequently Asked Questions

Discover More
4.5kA at 230/400V, IEC 60898-1, C curve, 63A, 2P in the listed model. Mechanical life 20,000 operations.
CONTACT US

Start Your Electrical Project Today

Send your application, voltage, certifications and quantity to this electrical protection manufacturer. We reply with a quotation within 24 hours.
  • Engineering review by an electrical protection manufacturer before quoting
  • Plant pricing with no intermediaries
  • Export packing and shipping handled in one place
  • One order owner from quotation to delivery