Contactor

WTAIELE builds AC and DC contactors from 6 A to 410 A for motor control, capacitor switching and DIN-rail boards, at our plant in Liushi, Yueqing.

AC, DC or 4-Pole: Which Contactor Range Fits the Circuit

Start with what the contactor has to switch, not with the model number. A three-phase induction motor on an AC supply takes a CJX2 frame sized on AC-3 current. A battery, solar string or 48 V DC bus takes a CJX2-Z frame, because the arc needs magnetic blowout that an AC frame does not have. Where the neutral has to break with the phases, or two single-phase circuits run through one device, it takes a four-pole frame.

Two smaller ranges cover the rest: CJ19 for capacitor banks, where the inrush is far above the rated current, and WTH8 for DIN-rail boards in apartments and small commercial panels.

Whichever range you open, the order needs three things: the frame current, the coil voltage of the control circuit, and the auxiliary contacts the panel logic uses.

Contactor products

Tell Us the Motor and the Control Voltage

Send the motor rating, the supply voltage and the coil voltage on the panel. We reply within 24 hours with the frame, coil code and auxiliary block, and confirm the stock position for the quantity.

ORDERING A CONTACTOR

Frame, Coil, Auxiliary: the Three Lines That Decide the Order

Most wrong orders start on one of these three lines. The frame is chosen on AC-3 current at the supply voltage, and a 5.5 kW motor at 380 V draws about 11.5 A, so the frame is a 12 A or 18 A unit rather than the next size up on the kW table.
The coil is chosen on the control voltage in the panel. A 220 V coil fed from a 380 V control circuit fails in minutes, and a 24 V coil on 12 V simply will not pull in. The coil code is part of the model, confirmed at order.
The auxiliary contacts decide the panel logic: 1NO is enough for a simple start circuit, 1NO+1NC is what a holding circuit with a stop button needs, and 2NO+2NC covers a PLC status input plus an interlock. Ordering them with the contactor keeps the panel from waiting on a second delivery.
Send those three numbers and we return the frame, coil code and auxiliary block, with the terminal layout.
Frame, Coil, Auxiliary: the Three Lines That Decide the Order
COMMON QUESTIONS

Frequently Asked Questions

A standard three-phase induction motor takes a CJX2 frame sized on AC-3 current at the supply voltage, with a coil matched to the control circuit. Add an overload relay for protection and an auxiliary block for the holding circuit. Above 95 A, step up to the CJX2-D or CJX2-F frame.

CONTACT US

Start Your Electrical Project Today

Send your application, voltage, certifications and quantity to this electrical protection manufacturer. We reply with a quotation within 24 hours.
  • Engineering review by an electrical protection manufacturer before quoting
  • Plant pricing with no intermediaries
  • Export packing and shipping handled in one place
  • One order owner from quotation to delivery